Victron MultiPlus-II 120 V 48/5000/70-95 Inverter/Charger
- Brand:
- Victron Energy
- Part no:
- PMP482505120
Image: Victron Energy
Where to buy
Specifications
- Type
- Inverter charger
- Continuous output
- 4000 W
- Rating in VA
- 5000 VA
- Peak output
- 9000 W
- Battery voltage
- 48 V
- AC output
- 120 VAC
- Charger output
- 70 A
- AC transfer rating
- 95 A
- Ingress rating
- IP22
Manuals and data sheets
- MultiPlus-II 120V manual (HTML)www.victronenergy.com
- MultiPlus-II External Transfer Switch application manual (HTML)www.victronenergy.com
- MultiPlus-II 120V data sheet (PDF)www.victronenergy.com
- Automatic Generator start-stop manual (HTML)www.victronenergy.com
- Connecting other lithium battery systems to Multis and Quattros manual (PDF)www.victronenergy.com
- Dynamic ESS manual (HTML)www.victronenergy.com
- Energy Storage System manual (HTML)www.victronenergy.com
- Solar & Wind Priority manual (HTML)www.victronenergy.com
- VictronConnect configuration guide for VE.Bus products (HTML)www.victronenergy.com
Full data sheet
Victron Energy, part number PMP482505120
Technical
- Continuous inverter AC output power at 25°C
- 4,000 W
- Maximum efficiency
- 96 %
- Maximum AC input current
- 95 A
- Fan assisted cooling
- Yes
- External AC Current Sensor
- 100A (optional)
- DC input voltage range
- 38 to 66 VDC
- Continuous inverter AC output power at 65°C
- 3,000 W
- Continuous inverter AC output power at 40°C
- 3,700 W
- Maximum humidity (non-condensing)
- 95 %
- Continuous power at 25°C (Nonlinear load, crest factor 3:1)
- 5,000 VA
- Programming via computer or app
- Yes
- General purpose communication port
- Yes
- Communication Port
- VE.Bus
- Charge voltage storage (adjustable)
- 52.8 VDC
- Charge voltage float (adjustable)
- 55.2 VDC
- Charge voltage absorption (adjustable)
- 57.6 VDC
- Charge algorithm
- Adaptive, 4-stage
- Protections
- Output short-circuit, Overload, High battery voltage, Low battery voltage, Over temperature, AC voltage on inverter output, Excessive DC ripple
- Zero load power in search mode
- 3 W
- Zero load power in AES mode
- 10 W
- Zero Load Power
- 15 W
- Transfer switch AC current rating
- 95 A
- Three phase operation
- Yes
- Temperature Sensor
- Included
- Remote terminal
- On / Off / Charger only
- Nominal battery voltage
- 48 V
- Programmable relay
- AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC
- PowerControl
- Yes
- PowerAssist
- Yes
- Peak power rating
- 9,000 W
- Parallel operation
- Yes
- Operating temperature range (fan assisted cooling)
- -40 to 60 °C
- Number of AC Outputs
- 2
- Number of AC Inputs
- 1
- Maximum charge current (up to 25°C ambient)
- 70 A
- Auxiliary AC output
- Yes
- AC output voltage ±2% (adjustable)
- 120 VAC
- AC output frequency ±0.1% (adjustable)
- 60 Hz
- AC input voltage range
- 90 to 140 VAC
- AC input frequency range
- 55 to 65 Hz
Connections
- Relay terminal type
- Screw terminal 3-pole
- Remote terminal type
- Screw terminal two pole
- VE.bus communication port
- Two RJ45 terminals
- Battery connection terminal type
- M8 bolts
- AC connection terminal type
- Screw terminals 35 mm² (2 AWG)
Enclosure
- Protection category
- IP22
- Weight
- 32 kg (70.5 lb)
- Width
- 330 mm (13.0 in)
- Material
- Steel
- Depth
- 164 mm (6.5 in)
- Height
- 676 mm (26.6 in)
- Color
- Blue (RAL 5012)
Standards
- Emission and immunity
- EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, EN-IEC 61000-6-1, EN-IEC 61000-6-2, EN-IEC 61000-6-3
- Safety
- EN-IEC 60335-1, EN-IEC 60335-2-29, CSA C22.2 107.1-16
A 120 V inverter/charger from Victron, this MultiPlus-II runs from a 48 V battery bank and delivers 4,000 W continuously at 25°C, with a peak rating of 9,000 W and 5,000 VA on nonlinear loads. The built-in charger can supply up to 70 A at 25°C ambient. Its transfer switch is rated 95 A. Output is 120 VAC, adjustable, and units can be run in parallel for more capacity.
Our take
Rated 4,000 W continuous at 25°C but only 3,000 W at 65°C, this unit gives up a quarter of its output as ambient temperature climbs, so size the load for the hot case. The 9,000 W figure is a peak rating, not a continuous one.
From our buying guide
On a boat subpart I covers, an electrical component must not ignite fuel vapor around it unless it is isolated from gasoline fuel sources. Ignition protection is the maker's statement.
Check before you buy:
- It can follow your battery's profile, since not every charger can follow a lithium maker's.
- On a boat subpart I covers, each ungrounded output conductor from a battery needs a manually reset, trip-free circuit breaker or fuse within 72 inches of the battery.