Skipper's Locker

Victron Centaur Charger 24/30(3) 120-240V

Brand:
Victron Energy
Part no:
CCH024030000

Where to buy

Specifications

Outputs (banks)
3
Output current
30 A
Ingress rating
IP20

Manuals and data sheets

Full data sheet

Victron Energy, part number CCH024030000

Technical

Operating temperature range
-20 to 50 °C
Number of charge outputs
3
Maximum humidity (non-condensing)
95 %
Total output ammeter
Yes
DC input voltage range
90 to 400 V
Nominal battery voltage
24 V
Charge algorithm
IUoU, three stage charging
Ignition protected
Yes
Forced cooling
Yes
Charge Current Nominal
30 A
Charge voltage Absorption
28.5 V
Charge voltage float
27 V
Output temperature derating
Up to 40°C (100°F) ambient. Output will reduce to approximately 80% of nominal at 50°C (120°F) and 60% of nominal at 60°C (140°F).
Recommended battery capacity range
120 to 300 Ah
AC input frequency range
45 to 65 Hz
AC input voltage range
90 to 265 V
Programmable
Charge voltages selectable via DIP switches
Protections
Output short-circuit, Over temperature
Temperature Compensation (adjustable)
-12 mV/°C
Temperature Sensor
Internal
Power factor
1

Connections

AC connection terminal type
screw-clamp 4 mm² (AWG 6)
Battery connection terminal type
M8 bolts

Enclosure

Protection category
IP20
Weight
5 kg (11.0 lb)
Width
239 mm (9.4 in)
Material
Aluminium
Color
Blue (RAL 5012)
Depth
110 mm (4.3 in)
Height
437 mm (17.2 in)

Standards

Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, UL 1236
Emission Immunity
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3

The Centaur Charger 24/30(3) is a charger for 24 V batteries with a nominal charge current of 30 A. It has 3 charge outputs and is ignition protected. Charge voltages are chosen with DIP switches. The recommended battery capacity runs from 120 to 300 Ah, and the enclosure carries an IP20 protection category. Output is held to 40°C ambient and falls to about 80 percent of nominal at 50°C.

Our take

The Centaur 24/30 is ignition protected and has three charge outputs from a 30 A nominal charge current, so one unit can charge several 24 V banks. Output falls to about 80 percent of nominal at 50°C, so keep heat in mind.

From our buying guide

NMMA says charging sources must meet the charging profile the battery maker recommends. A charger's presets are its own maker's, not the battery's, so set it from the battery maker's figures.

Check before you buy:

  • It can follow your battery's profile, since not every charger can follow a lithium maker's.
  • Its output suits your bank. ProMariner recommends about 10 percent of the batteries' total amp-hour capacity, with one charger output for each battery.
  • It suits how you'll use it, since ProMariner says its waterproof chargers are for batteries not in use while charging.

See all battery chargers

Sources