Rated flow
1100 gal/h
Automatic
Electronic sensor
Outlet
25.4 mm
Voltage
12V
Current draw
3.8 A
Flow at stated head
1128 GPH at 0 ft; 792 GPH at 3.3 ft; 456 GPH at 6.7 ft

Rule's automatic 1100 GPH bilge pump (RM1100B), which senses water with an internal level sensor, so no float switch is needed; if debris fouls the sensor, it falls back to checking for water every 2.5 minutes. Rule's Rule-Mate manual (950-0535 Rev E) gives 1,128 GPH at zero head but 792 GPH at 3.3 ft and 456 GPH at 6.7 ft, without stating a test voltage. It draws 3.8 A at 12 V on a 7.5 A fuse, and Rule says it is for normal bilge water, not damage control.

From our buying guide

Rule and Johnson both say their bilge pumps are not intended for damage control. Flow falls as the discharge head rises, and the length of the hose, its bends and any check valve reduce it further.

Check before you buy:

  • The maker's own table shows the flow at head, since how much a pump loses depends on the model.
  • An automatic pump also has a manual switch, which ABYC's voluntary 2005 standard calls for.
  • You'll fuse it to the maker's figure.